!function(f,b,e,v,n,t,s) {if(f.fbq)return;n=f.fbq=function(){n.callMethod? n.callMethod.apply(n,arguments):n.queue.push(arguments)}; if(!f._fbq)f._fbq=n;n.push=n;n.loaded=!0;n.version='2.0'; n.queue=[];t=b.createElement(e);t.async=!0; t.src=v;s=b.getElementsByTagName(e)[0]; s.parentNode.insertBefore(t,s)}(window, document,'script', 'https://connect.facebook.net/en_US/fbevents.js'); fbq('init', '366319058984917'); fbq('track', 'PageView');
15 minutes read
25 January 2021

Web under local loads – Linear FEA

15 minutes read

In the previous post, we solved a rather interesting case of local loading in webs. We did those calculations by hand, following the procedure of EN 1993-1-5. While I really like hand calculations, it’s obvious that you can’t hope for a code procedure for every possible case…

When there are no clear guides on how to solve a problem by hand, FEA is your best friend! You can model everything you need, and analyze it – solving an otherwise unsolvable problem. Without a doubt, linear FEA analysis is the most commonly used tool in this regard.

And this is what we will do today! We will try to solve the same problem, using the linear FEA approach – this will give us an opportunity to see if this is useful at all in our case!

The problem at hand!

I already described the problem previously, but we will need the details here as well! The picture below shows what the arrangement looks like. The bottom beam is pushed downward, and we need to estimate how much load we can apply this way, before the web of the lower beam fails.

The only thing I haven’t marked above are the grey stiffeners. They are 10mm wide, and 100mm apart (the span in the middle is 800mm wide).

I must confess that I’m using a dirty trick here! Normally, when I design a beam I would instantly go with the “height” from the center of one flange to the center of the other flange. This means, that I would model the bottom beam as 530mm high. This is 500mm for the web and an “additional” 15mm per flange. This would lead to the most accurate Section Modulus and is generally a good practice you should follow.

However, this also means, that my FEA model would “see” the web as 30mm “higher”. And since we are ONLY focusing on the web here, I will model the beam as 500mm high. This won’t have a “dramatic” impact on the outcomes, but I figured I may as well be “on point” here.

Just please note:

I do this ONLY because it’s a partial model that focuses on calculating ONLY the web and its stability. You want to use centerlines in all true design cases. Unless a very good argument can be made to do it differently!

That being said – we have everything we need to do the analysis. If you would like to give it a shot, below you can download the geometry for the problem:

Download the Geometry

Ready, Steady, FEA!

This is funny because the hand calculation procedure required a long description before we started. Here, the comment would be… you know, just do FEA!

Of course, the first thing we should do is to mesh and support the model. This is a super simple thing, so I will move “swiftly” here, without going into too much detail. If you really need to know: no, I did not do a mesh convergence check!

The above model most likely tells you all. The red lines (on the entire length under the middle stiffeners) are just “pinned”. Notice that this means, that I blocked vertical deformations (for whatever reason it’s Y in this model… I must have been tired!) on the entire length of those lines! This means, that the model cannot rotate around Z axis, which makes the affair stable!

The top beam is simple. I defined the contact between the top and bottom beam of course. But I need to introduce the load to the top beam somehow. I decided to make a rigid outline using RBE2 elements on both ends (all nodes on the selected lines (in blue above) are connected with RBE2 to one central node. That node is loaded in the vertical direction, but is also supported. On the “+X” side I blocked Tx=Tz=0, on the “-X” side I blocked Tz=0. I selected this scheme, because I didn’t want the top beam to do “funny” things between the Tx supports on both ends… so I simply didn’t block that direction on one end!

The load is simple – I can just apply any vertical load on both central nodes of RBE2 elements. I should aim to apply the same load on both ends of course!

And this is the first “funny thing”… since I want to check what is the maximal capacity… what load should I apply? This is a rather tricky thing, so I did what any good engineer would do: I cheated!

Since we already did the hand calculations, I simply took the outcome of those (315.8kN) and divided it equally on both sides (so 157.9kN each). This seems like a perfect start right?

You can see the model setup on the below video:

It’s all about the outcomes!

Firstly, let me start with showing you the outcomes:

If you usually work with linear FEA you already know that there is guessing ahead! The maximal stress we obtained is 328MPa! This means that since the yield strength of steel is S235, we are around 40% above yield stress. And so, the “fun” begins!

It’s quite hard to see where the stress is higher than yield, so I modified the stress scale a bit, to make it more visible:

I think it’s quite obvious, that the maximal stress is perfectly below the beam transferring the load. Precisely in the place, we are analyzing! So the question appears – is this “acceptable”? And I must add, that this is one of the most common questions I receive from my subscribers.

The real, and down to earth answer is: Nobody knows if this stress is “acceptable”!

And that is the main problem with linear FEA! In fact, you will be able to read a lot more about it in the post that I will publish in a few weeks!

What things are you willing to ignore…

I already stated, that “nobody knows” what stress is acceptable. There are no “golden rules” etc. All I can tell you is what I would accept, and why.

But to make it more fun – you go first! Take a look and note, which of the below stress distribution would you “still” allow in design?

Note that the dark blue means “stress below yield” and every other color is “above yield” according to the scale on the right. Of course, load is getting higher and higher as we progress from A to F!

Have you selected the case, you would be willing to choose as “still acceptable”? I hope you did!

To be honest, it doesn’t really matter which one you have chosen. The real question is: why you’ve chosen that one!

You see… I don’t know any rules that would govern this choice. Simply put, from my perspective, it’s just guessing! And this is a super dangerous thing if you are not aware of this! Note, I’m not saying that this is immoral or something. I did this kind of guessing at the beginning of my career as well (and for quite some time, as my company was saving up money for a better solver!). There is nothing “inherently wrong” with guessing… but you totally have to be aware that this is a guess!

So, while I would not base my design on such a guess nowadays (as I did in the past!) I’m more than happy to guess with you! This also gives me the chance to share my thought process with you!

My choice would be C! This stress distribution would happen if I would apply a total load of 380kN. Or, if you prefer to think about it this way, at a load 1.2 times higher than the capacity from hand calculations we did previously. First of all, I totally ignore the stress value. As you will soon learn sometimes this value can be insane… so I already know this may not be a good metric. Of course this only applies with a 2D or 3D mesh! Never ignore stresses given by your beam models!

That said, what I see in E is, the width of the yielded zone is bigger than the width of the flange of the top beam. Simply put, the beam “stands” on a completely yielded web. I would say that D is “on point” with the width (by eye, I haven’t really measured it). But I thought, that maybe the web would buckle or something, so having “extra safety” would be wise. On the other hand, B (which is for load 315kN – the outcome from hand calculations!) seems to have a small yielded zone, which should do just fine… so C seems like a natural choice.

I’m also afraid this is as “precise” as I can go. If there were 3 answers around the value of C (you know, with max stress of 390MPa, 395MPa, and 400MPa)… I would just say “pick whatever, I don’t know”! Simply put, there is a certain level of accuracy over which I feel “blind”!

There are two additional considerations in my mind:

  • Option C can be a bit conservative since in my considerations I completely ignored the top flange of the big beam. It will “help” spread out the load on a greater width of the web, especially when the yielding of the web starts. So there is a chance that the outcome will be “better”. Of course, I’m more than happy to ignore things that “work in my favor” – there is no risk in that!
  • On another hand, I’m not sure how big a stability problem we may have here… and maybe even C is an optimistic answer? This is a problem of course, and I feel the guess I did already, is not “educated enough” as of yet! We need to investigate stability too!

As you can see, while I know a bit about the model and about the phenomenon, I’m still guessing the answer! And while it may be educated, basing the prediction on such linear FEA outcomes is a guess! No worries, we will check how close I was (and you were!) next time, when I do the nonlinear analysis of the same problem!

But for now, let’s try to squeeze as much from linear FEA as we can! This way, our guess can be even more educated!

Don’t forget about stability!

I’ve been on an online nonlinear FEA course once, where linear buckling was discussed in detail. I do agree that stability is definitely a difficult thing just as nonlinear FEA is. But I totally disagree with “adding” LBA to the “nonlinear kingdom”. If we did that, I would argue that much of the “linear FEA design” would make no sense, as you would have no chance of taking stability into account at all!

And while I really felt like a hacker the first time I did LBA analysis on a 2D meshed model… this is still a “linear thing”. After all, it’s even called LINEAR buckling (well, Linear Bifurcation Analysis to be precise, but who cares – it’s the same thing!).

So I feel 100% justified to use LBA in the “linear FEA” portion of our analysis! The cool thing is, that nowadays a lot of linear solvers have the capacity to perform linear buckling, so it’s not so uncommon!

As in the previous case, I loaded my model with the maximum load obtained from hand calculations. This means, that the total applied load is: 315.8kN just as we discussed already. In such a case, LBA outcomes look like this:

While the viewing angle is a little awkward(so you can see what is happening directly under the top flange) the most important information is there! The critical load multiplier is 2.598. This means, that the critical load (the load that causes stability failure of an ideal, elastic model) is 2.598 * 315.8kN = 820.4kN (or 2.6 times “the load” which is capacity obtained from hand calculations).

This is as much as we will get from linear buckling. Introducing imperfections makes little sense. Mostly, because LBA is a linear algorithm, so it won’t “see” second-order effects anyway!

The question remains: do I like this outcome?

Honestly, I haven’t analyzed plate buckling with LBA enough to have a definitive opinion. But I’m more than happy to share a few thoughs:

  • It may seem that the outcome of 2.6 is awesome… it’s not! This is not as if it’s a 2.6 factor of safety or anything like this! Models never fail as an “ideal, elastic” since… they are not ideal, and in most cases, they are not elastic either! This means that the “actual” capacity due to buckling will be much lower – just as the column capacity to compression is lower than the critical force in that column!
  • Plates are quite stable! This is something I “just know”. I can’t even recall where I know this from, but I would guess it must have been part of the studies for my Ph.D. Plates are super stable since a “well supported” plate in compression has a stable post-critical path. This sounds overly scientific perhaps, but the idea is, that while the column fails after buckling, some plates have a tendency to just “lose some rigidity” but still work! This is a super neat thing. Just remember that shells are the complete opposite of that! This means, that while a 2.6 critical load multiplier for a shell might be a complete catastrophe, for a plate it may be ok!
  • This doesn’t work alone! It’s not as if anything has a distinctive capacity for stress and a separate capacity for stability (not to confuse things, I would refer to this one as “critical” capacity… as in LBA outcome). But it’s pretty useful to think about it this way! Imagine that you have a “stress” and “critical” capacity. Just be aware, that neither of them is the “actual capacity” of your model! Those two, if they are “close to each other in value” will work together (reducing the final capacity below both!). So assuming that I accept the 380kN of the load as a “stress capacity”, this doesn’t include the impact stability will have on capacity. And with a critical load of 820kN (“the critical capacity”), I should expect the final capacity to be lower than either “stress” or “critical” capacity since 380kN and 820kN are “quite close” in my opinion!

What do we learn from all of this?

In the “stress design” I was choosing between these options:

As you recall, I felt ok with the answer “C”. I mentioned that while I think D is ok(ish) with the stresses, I want to have extra safety because of buckling. And I’m glad that I did that!

If the LBA would give me a multiplier of 15 or something, I would be “tempted” to get back to “D” as my chosen answer. But with a critical load equal to 820kN, things are way more tricky (this is such a cool example, isn’t it?!). I need to remember, that LBA used elastic material (and no imperfections) in estimating that critical load. This means, that since answer C “allows” for quite some yielding, the real answer will be worse than the 820kN I got from LBA (it’s always worse!).

So the real question is: Do I think that the yielding that I see in C, with imperfection influence (that I can only guess here!) would reduce the actual capacity “a lot”? By “a lot” I mean, will the “critical” capacity influence the “stress” capacity significantly? This is a hard one, as I’m really not sure. I already wrote that I’m willing to accept 380kN as the answer based on stress. At least, as long as we treat the load as a design value! But will the stability reduce the capacity so much, that I should not allow for such load? Here, it’s pure guesswork!

Want to learn about FEA? Get my free FEA Video Lesson

Learn the most valuable FEA lessons that will greatly speed up your learning about:

  • Boundary Conditions
  • Meshing
  • Loads
  • … and so much more!

Watch the video today, and skyrocket your FEA skills!

Get the lesson here

I think this is a borderline thing. Critical capacity (820kN) is quite close to the one I guessed as a stress capacity (380kN). So I will guess, that they will “work together” a bit, reducing the final capacity of the model, even below the value of either of them! And this leads me to the final guess of 350kN!

My guess includes both stress capacity, and “critical” capacity, and I even tried to take into account that these two failure modes will “work together” to further reduce the capacity! I guess this is “as far” as you can go with linear FEA!

SUPER IMPORTANT THING!

Since I work with nonlinear FEA, and I know quite a few things about stability, I may be quite courageous with my “guessing”! But even with my knowledge, I would NOT base my design on such guessing… anymore!

When I was using linear FEA for design, I knew much less about this whole mess… and I was way less courageous! This means, that now when I use nonlinear FEA, I can suspect that the capacity of my model is even higher than the one I guessed here. But even knowing that, I would not allow for such guessing in design. And when I was guessing… I was guessing way more conservative than what I showed you here!

Please, do not treat this as an encouragement to “risk” anything! After all, I’m totally guessing here, and you should be very careful while doing your designs!

Thank you for being here with me!

I hope you like this journey so far. Definitely let me know what you think in the comments below.

Author: Łukasz Skotny Ph.D.

I have over 10 years of practical FEA experience (I'm running my own Engineering Consultancy), and I've been an academic teacher for a decade. Here, I gladly share my engineering knowledge through courses, and on the blog!

Read more

Join my FEA Newsletter

Get my 1h video lecture:
6 Essential FEA Lessons

    Your personal data administrator is Enterfea Łukasz Skotny, Skrzydlata 1/7, 54-129 Wrocław/POLAND, Email. By subscribing to the newsletter that includes marketing messages you consent to your personal data processing in accordance with this privacy policy

    Join the discussion

    Comments (8)

    Łukasz - 2021-12-15 10:17:33

    The 'guess' method shown here is not a correct engineering approach. Don't you think using that way you can always get similar results to hand calculations you made before?

    Reply
    Łukasz Skotny Ph.D. - 2021-12-19 00:31:04

    Hey!

    Well, yea, that would obviously be the case - if I would know the answer to the problem, I could easily "guess" that answer... but that is the whole point! There are a lot of engineers using this "guessing" method as the only design method... which basically means, that they are guessing their outcomes, although the guesswork looks very "professional" and with nice pictures...

    I'm absolutely not telling you to follow this (in fact, please read the other posts in this series to learn what I think) - but if you would like to rely on "linear FEA" and nothing else in design - I do believe that this would be the methodology.

    All the best!
    Ł

    Reply
    Ricardo - 2021-02-03 19:35:06

    Thanks, great stuff as always, can´t wait for the non linear part!

    Reply
    Łukasz Skotny Ph.D. - 2021-02-06 07:35:35

    Thank you, Ricardo!

    I'm really glad that you like it!
    Ł

    Reply
    arturo n.salgado - 2021-01-26 16:44:11

    I feel that the real stress distribution for linear analysis it must be similar to the upper image of the lba analysis near to the union of the two beams or only bearing press, the buckling I don´t believe that exist we are trying in local stress (it is not macrobalance L>>height)

    Reply
    Łukasz Skotny Ph.D. - 2021-01-27 08:02:43

    I must confess I have a difficulty in understanding your comment... you don't believe that buckling exist?

    I'm sure this is not what you mean, or at least I doubt that this is what you meant - if you could clarify a bit, perhaps I will be able to reply in a more meaningful way.

    All the best!
    Ł

    Reply
    FEA_enthusiast - 2021-01-26 10:35:29

    1. this is not a linear analysis if you add contact. Contact is always nonlinear analysis. Maybe you didn't employ geometrical nonlinearity (which you constantly call "nonlinear geometry", what is not clear or even wrong to use). Correct me if contact is not used here.
    2. load - displacement curve for upper beam would clearly show if this is linear or nonlinear analysis.
    3. LBA is linear because it assumes that before buckling response is linear. But second-ordetr effects (small displacements affects equlibrium) are taken into account, what results in nonlinear geometrical matrix calculated and used to find load multipliers. There are also 3rd and 4th order effects, used in "fully nonlinear" analysis.
    4. can you justify any how why stresses are wrong metric in 2d and 3d models while shouldn't be ignored in beam models? Maybe you have mentioned in previously on your blog.

    Reply
    Łukasz Skotny Ph.D. - 2021-01-27 08:00:20

    Hey Mate,

    1. There will always be semantic debates about how things should be called or classified. I think I even have a post about this somewhere, but I also have a strict policy not to take part in those. I'm really sorry that you do not like the terms I'm using and that you consider them wrong, and I'm sure you are right to claim so. I'm not a theoretician, so maybe nonlinear geometry and geometrical nonlinearity are two completely different things - to me, it just means the same, and I use the terms interchangeably (it's a direct translation from Polish where "geometryczna nieliniowość" and "nieliniowa geometria" is the same thing as far as I know). I will try to be more cautious about this, but I can't do any promises - it's just a habit.
    If I recall I did use contact, but still Femap would call that a "linear analysis". But again, we could discuss this till we die, and in the end - who cares? The idea is that both geometry and material are linear and this is what I meant. I think this is obvious for all the readers... but maybe I'm wrong.
    2. Sure
    3. I think we would have to dive deep into who understands what under the 2nr, 3rd, and 4th order effects... but it's semantics once more... and I'm not even sure where are you want to go with this.
    4. I don't like justifying stuff, as it would suggest that I'm accused of something or did something wrong, wouldn't it? But I will gladly answer your question, which is a way more friendly way of asking for knowledge, wouldn't you agree? In 2D and 3D mesh it's extremely easy to generate stress concentrations that may not be "real" and come from FEA (I'm not saying ignore them, I'm just saying "it's complicated"). Beam models super rarely have that kind of problem (sometimes is super short elements you get weird shear, but I guess this is the only thing that comes to my mind). So stress in beams is way more reliable in that regard (and again, I'm not saying "ignore the rest" at all!).

    In the end, I have a semi-personal question for you if you don't mind. Are you working as a teacher/scientist at any University?

    All the best!
    Ł

    Reply

    Sign up for my FEA Newsletter!

    Each Tuesday you will get awesome FEA Content directly to your email!

      Your personal data administrator is Enterfea Łukasz Skotny, Skrzydlata 1/7, 54-129 Wrocław/POLAND, Email. By subscribing to the newsletter that includes marketing messages you consent to your personal data processing in accordance with this privacy policy